Firmware Release Notes
Firmware Release Notes
Pico
Pico v0.0.57-r57 · 11.9.2026
Bugs:
-
Fix pico station idle after pause transaction stays open
-
Fix false overload trip of the 130% overcurrent protection
Pico v0.0.55-r55 · 01.05.2026
Bugs
-
EM-406: Improve uart and watchdog
-
Quick Fix WiFi AP mode
Pico v0.0.54-r54 · 13.04.2026
Bugs:
- Multiple improvements have been made to ensure better WLAN, mesh, and mobile connectivity.
Pico v0.0.53-r53 · 12.03.2026
Feature
-
Show "waiting for current" screen when the loadmanagement can not assign current to a station
-
Show Warning on Screen and cloud when CP is 0V
-
Show Error on screen when the Meter-SOM communication has failed
-
Change default min. current to 8A and disable car id per default
-
EM-348: RFID Card Installation Process Implementation
-
EM-319: Don't show the heat warning on the display. Only show it on the cloud
-
1 Phase Charging
Bugs:
-
EM-380: pico mesh nodes not joining the lm group
-
EM-396: Wrong Loadmanagement offline behavior
-
EM-379: Current balance not working on a group with single phase station
-
Meter-SOM SPI communication error (Should fix Meter-SOM communication after reboot)
-
Fix Bug in DNS resolution (WiFi)
-
Fix PLC (car id) waiting time
-
Fix charging statemachine timing
-
Set current to 0A before doing an unlock cable or reboot
-
Wait until the wifi Module is up and running before doing something (e.g. turn on the relais). This should avoid problems during the ESP32 Update.
-
Access Point Mode (installation) sometimes does not start
-
Reboot the wifi module after 5min of controller inactivity
-
Fix 1-byte UDP packet truncation in mesh-forwarded parallel Arm updates
-
Validate if required firmware files exist at startup
-
firmware update improvements
-
EM-368: Lexus stops charging after 30min
-
EM-367: Activate with RFID - Car goes into error state first
-
EM-366: Station stops charging when the wifi module restart due offline timeout
-
Fix integer overflow panic in display_module.rs time calculation
-
EM-362: Unable to connect to Installation AP
-
WiFi: decoupling Timer execution context
Pico v0.0.47-r47 and 0.0.46-r46 · 01.12.2025
-
Option to switch between 1-3 phases via Modbus or API. (MLM is not yet supported)
-
internal improvements
Pico v 0.0.37-r37 and 0.0.36-r36 · 14.08.2025
Bug fixes
Pico v0.0.34-r34 · 16.01.2025
Bug fixes
- EM-336: Fix WLAN Installation Problem
Pico v0.0.33-r33 · 06.01.2025
Features
-
EM-281: Loadmanagement: Free the reserved current (6A) for paused stations
-
EM-172: Loadmanagement: The current when to change from 3-phase to 1-phase charging is now adjustable in the cloud
-
EM-172: Loadmanagement: Max. current (per station) for 1-phase charging
-
EM-329: Loadmangement: Increase from 1-phase to 3-phase charging is now possible. The setting to enable / disable it is in the cloud
-
Installation: WLAN in installation mode has now a Password ("smart-me"), for Picos >= 7005567 and (7003152 - 7005229)
Bugs
- Mobile connection stability increased
Pico v0.0.30-r30 · 03.10.2024
- EM-320 Fix possible loss of charging transactions in communication (mostly mobile)
Pico v0.0.29-r29 · 1.7.2024
Features
- EM-245: Load management: Reset from 1-phase to 3-phase, even if cars in the group are being charged.
Bugs
-
EM-311: Adjust Temperature Limits
-
EM-307: Improved offline behavior
Pico v0.0.28-r28 · 15.04.2024
Features:
-
New Authorize Images Flow and Animation (RFID, CardId) (EM-264)
-
PLC Timeout removed (changed from 25s to 3s)
Bugs
-
Improve Offline detection
-
WiFi improvements
Version 0.0.25-r25 · 10.01.2024
Features:
- SIM7070 Support
Bugs
-
Improved Mobile Connection
-
Show "Failed" Screen when Authorize with RFID card was not successful
-
Loadmanagement: Calculated current unbalance index returning wrong value
-
Loadmanagement: Load manager doesn't increase station current for specific condition
Technical:
- upgrade aes soft algorithm
Pico v0.0.23-r23 · 07.12.2023
Features:
- Dynamic Current on Lost connection for Loadmanagement Group
Bugs
- EVSE Tool fixes (try to restart it after a crash)
Pico v0.0.22-r22 · 04.09.2023
Bugs
- Fix problem with locker with very cold temperatures (below -20 degree C)
Pico v0.0.21-r21 · 27.08.2023
Features
-
Stop charging when disable calibration mode (for transaction validation in production)
-
Increase routing lookup table for wifi module (support upto 200 stations per loadmanagement group instead of 20)
Pico v0.0.20-r20 · 03.07.2023
-
Show date/time (start time of the charging and the duration) in the charging screen
-
Show the current used and allowed in the power screen
-
Do RCD Test every 24h in State A
-
Use lower baudrate if WiFi Update fails
Pico v0.0.19-r19 · 08.05.2023
- Fix Bug in Charging Statemachine (Wait in State B1 until we have a PWM before switch on the relais)
Pico v0.0.18-r18 · 03.04.2023
-
Buffer images (reduce reads from flash)
-
RSSI (signal quality) for wifi and mobile support
-
Flush to disk (flash) after writing the settings file or the images / firmware updates
Pico v0.0.17-r17 · 17.02.2023
-
Timing changes to power start up after car is ready (enhanced car type support)
-
Internal optimizations
Version 0.0.16-r16 · 16.12.2022
- Internal optimizations
Version 0.0.15-r15 · 12.12.2022
-
Enhance Pico load shedding for single stations
-
Internal optimizations
Version 0.0.14-r14 · 06.12.2022
- Show energy consumption at the end of charging
Version 0.0.13-r13 · 09.11.2022
- Internal optimizations
Version 0.0.12-r12 · 06.12.2022
- Internal optimizations
Version 0.0.11-r11 · 11.10.2022
-
Warnings and errors enhancement on cloud
-
Bugfix: Loadmanagement dynamic current
Version 0.0.10-r10 · 23.09.2022
- Bugfix: CarID detection
Telstar 80A / Telstar CT
Version 9 (V18 and V19) · 19.09.2023 (beta test ran until 08.2024)
Bug fixes:
- Fix Modbus TCP (only 255 connections problem)
Version 8 (V16 and V17) · 12.04.2023
Bug fixes:
- Fix stop "start wifi" after disconnection from AP in special cases
Version 7 (V14 and V15) · 16.01.2023
Bug fixes:
-
Modbus TCP Timeout (idle clients will be disconnected after 5min)
-
Modbus TCP limit max number of clients to 4
-
Disable mesh connect when Modbus TCP is enabled
-
Connect to mesh network when connection to normal wifi AP fails for 16 times
Technical:
- Internal Updates for ESP
Version 6 (V12 and V13) · 19.02.2022
Bug fixes:
-
Modbus TCP heap overflow (on start modbus)
-
Deadlock in DNS resolution with wifi without internet connection
Version 5 (V10 and V11) · 21.02.2022
Bug fixes:
- Power Event action was factor 10 wrong
Version 4 (V8 and V9) · 11.02.2021
Bug fixes:
- Fix Modbus TCP Bug
smart-me reserves the right to implement features and bug fixes that are not communicated, particularly where internal matters are concerned.